Urine Toxicology Control
A urine based control designed for use in drugs of abuse screening at concentrations 25% above and below the SAMHSA recommended cut off levels. Assayed
target values and ranges are provided for 16 drugs of abuse, compatible for use on most clinical and immunoassay analysers.
-
Liquid ready to use
- Suitable for quantitative and semi-quantitative use
- Level 3 - High Positive
- Stable to expiry date at +2 - 8oC
- Open vial stability of 30 days at +2 - 8oC
Analytes
-
Amphetamines
- d-amphetamine
- d-methamphetamine
- Propoxyphene
- Barbiturates
- Phenobarbital
- Secobarbital
- Benzodiazepines
- Cannabinoids
- Cocaine
- LSD
- Methadone
- Opiates
- Free Morphine
- Buprenorphine
- Phencyclidine
- Ethanol
- TCA
| Description |
Size |
Catalogue Number |
| Drugs of Abuse Control Level 1 |
10 x 10ml |
DC1363 |
| Drugs of Abuse Control Level 2 |
10 x 10ml |
DC1364 |
| Drugs of Abuse Control Level 3 |
10 x 10ml |
DC1365 |
Cannabinoid Control and Calibrator
Dedicated calibrator and control set designed for the calibration and quality control of the Randox Cannabinoids assay.
-
Liquid ready to use
- Stable to expiry date when capped and stored at +2 - 8oC
| Description |
Size |
Catalogue Number |
| Cannabinoid Calibrator |
5 x 3ml |
DA2700 |
| Cannabinoid Control Level 1 |
5 x 3ml |
DA3127 |
| Cannabinoid Control Level 2 |
5 x 3ml |
DA3128 |
Ecstasy Control and Calibrator
Dedicated calibrator and control set designed for the calibration and quality control of the Randox Ecstasy assay.
-
Liquid ready to use
-
Stable to expiry date when capped and stored at +2 - 8oC
| Description |
Size |
Catalogue Number |
| Ecstasy Calibrator |
5 x 10ml |
DA2701 |
| Ecstasy Control Level 1 |
5 x 5ml |
DA3125 |
| Ecstasy Control Level 2 |
5 x 5ml |
DA3126 |
EDDP Control and Calibrator
Dedicated calibrator and control set designed for the calibration and quality control of the Randox EDDP assay.
-
Liquid ready to use
- Stable to expiry date when capped and stored at +2 - 8oC
| Description |
Size |
Catalogue Number |
| EDDP Calibrator/Control Set |
5 x 10ml |
DA2702 |
| EDDP Control Level 1 |
5 x 5ml |
DA3123 |
| EDDP Control Level 2 |
5 x 5ml |
DA3124 |
Ethanol Calibrator/Control Set
Dedicated calibrator and control set designed for the calibration and quality control of the Randox Ethanol assay.
-
Liquid ready to use
-
Stable to expiry date when capped and stored at +2 - 8oC
| Description |
Size |
Catalogue Number |
| Ethanol Calibrator/Control Set |
5 x 10ml |
DA2703 |
Multidrug calibrator
Multi-analyte calibrator and control set designed for the calibration and quality control of the Randox Amphetamines, Barbiturates, Benzodiazepines,
Cocaine Metabolite, Methadone and Opiatese assays.
-
Liquid ready to use
-
Stable to expiry date when capped and stored at +2 - 8oC
Analytes
-
Amphetamines
- Barbiturates
- Benzodiazepines
- Cocaine Metabolite
- Methadone
- Opiatese
| Description |
Size |
Catalogue Number |
| Multidrug Calibrator/Control Set |
5 x 10ml |
DA2704 |
Multidrug Control
Multi-analyte control designed for use in the quality control of the Randox Amphetamines,
Barbiturates, Benzodiazepines and Methadone assays.
-
Liquid ready to use
-
Stable to expiry date when capped and stored at +2 - 8oC
Analytes
- Methamphetamine
- Secobarbital
- Oxazepam
- Methadone
| Description |
Size |
Catalogue Number |
| Multidrug Control Level 1 |
5 x 5ml |
DA3121 |
| Multidrug Control Level 2 |
5 x 5ml |
DA3122 |
Benzodiazepines Control and Calibrator
Dedicated control and calibrator for use with the Randox Benzodiazepines assay.
-
Liquid ready to use
- Open vial stability of 28 days at +2 - 8oC
Analytes
| Description |
Size |
Catalogue Number |
| Benzodiazepines Control Level 1 |
5 x 5ml |
DA3130 |
| Benzodiazepines Control Level 2 |
5 x 5ml |
DA3131 |
| Benzodiazepines Calibrator Series |
5 x 10ml |
DA3129 |
Drugs of Abuse Array 1 Controls
A comprehensive control designed for use in the routine monitoring of accuracy and precision on Randox Biochip systems. Values in the level 1 control are below the SAMHSA cut-off for urine only while values in the level 2 control are above the SAMHSA cut-off for urine only. A High Opiate control is also available with a cut-off value of 2000ng/ml.
- Lyophilised for enhanced stability
- Stable to expiry date at +2-8°C
- Urine - Reconstituted stability of 14 days at +2-8°C or 28 days at -20°C
- Urine Semi-Quantitative - Reconstituted stability of 7 days at +2-8°C or 28 days at -20°C
- Whole Blood - Reconstituted stability of 14 days at +2-8°C
- Oral Fluid - Reconstituted stability of 7 days at +2-8°C
- High Opiate - Reconstituted stability of 14 days at +2-8°C or 21 days at -20°C
Analytes
-
Amphetamine
-
Barbiturates
-
Benzodiazepine 1
-
Benzodiazepine 2
-
Cannabinoids
-
Cocaine Metabolite
-
Methadone
-
Methamphetamine
-
Opiates
-
Phencyclidine
-
Creatinine
| Description |
Size |
Catalogue Number |
| Drugs of Abuse Array 1 (Urine) Controls |
2 x 4 x 1ml |
EV3551 |
| Drugs of Abuse Array 1 (Urine, Semi Quant) Controls |
2 x 4 x 1ml |
EV3630 |
| Drugs of Abuse Array 1 (Whole Blood, Semi Quant) Controls |
2 x 4 x 1ml |
EV3627 |
| Drugs of Abuse Array 1 (Whole Blood) Controls |
2 x 4 x 1ml |
EV3677 |
| Drugs of Abuse Array 1 (Oral Fluid) Controls |
2 x 4 x 1ml |
EV3649 |
| Drugs of Abuse Array 1 (High Opiate) Controls |
2 x 4 x 1ml |
EV3647 |
Drugs of Abuse Array 1 Plus Controls
Assayed control for use in monitoring the accuracy and precision on Randox Biochip systems. Two levels of control are provided covering the cut-off range.
- Lyophilised for enhanced stability
- Stable to expiry date at +2-8°C
- Urine - Reconstituted stability of 14 days at +2-8°C
- Whole Blood - Reconstituted stability of 7 days at +2-8°C or 14 days at -20°C
Analytes
- Amphetamine
- Barbiturates
- Benzodiazepine 1
- Benzodiazepine 2
- Buprenorphine
- Cannabinoids
- Cocaine Metabolite
- MDMA
- Methadone
- Methamphetamine
- Opiates
- Phencyclidine
- Tricyclic Antidepressants
- Creatinine
| Description |
Size |
Catalogue Number |
| Drugs of Abuse Array 1 Plus (Urine) Controls |
2 x 4 x 1ml |
EV3745 |
| Drugs of Abuse Array 1 Plus (Whole Blood) Controls |
2 x 4 x 1ml |
EV3750 |
Drugs of Abuse Array 1 (Urine) Control - Multistat
Multi-analyte control designed for use in the routine monitoring of both accuracy and precision of urine drugs of abuse on the Evidence MultiStat analyser. Assayed
values provided for 10 parameters.
Analytes
- Amphetamine
- Barbiturates
- Benzodiazepine 1
- Benzodiazepine 2
- Cannabinoids
- Cocaine Metabolite
- Methadone
- Methamphetamine
- Opiates
- Phencyclidine
- Creatinine
| Description |
Size |
Catalogue Number |
| Drugs of Abuse Array I (Urine) Evidence Multistat |
3 x 1ml |
EV3731 |
Drugs of Abuse Array 1 (Whole Blood) Control – Multistat
Multi-analyte control designed for use in the routine monitoring of both accuracy and precision of whole blood drugs of abuse assays on the Evidence MultiStat analyser. Assayed values provided for 10 parameters.
- Lyophilised for enhanced stability
- 1 year shelf life from date of manufacture
- Reconstituted stability of 7 days at +2 - 8°C or 28 days at -20°C
Analytes
- Amphetamine
- Barbiturates
- Benzodiazepine 1
- Benzodiazepine 2
- Buprenorphine
- Cannabinoids
- Cocaine Metabolite
- MDMA
- Methadone
- Methamphetamine
- Opiates
- Phencyclidine
- Tricyclic Antidepressants
- Creatinine
| Description |
Size |
Catalogue Number |
| Drugs of Abuse Array I (Whole Blood) Evidence Multistat |
3 x 1ml |
EV3734 |
Drugs of Abuse Array II Controls
A comprehensive control designed for use in the routine monitoring of accuracy and precision on Randox Biochip systems. Assayed values are provided for 10 parameters.
- Lyophilised for enhanced stability
- Stable to expiry date at +2-8°C
- Urine - Reconstituted stability of 7 days at +2-8°C or 28 days at -20°C
- Whole Blood - Reconstituted stability of 7 days at +2-8°C or 28 days at -20°C
Analytes
- 3,4 Methylenedioxymethamphetamine (MDMA)
- Ketamine
- Lysergic Acid diethylamide (LSD)
- Methaqualone
- Buprenorphine
- Fentanyl
- Generic Opioids
- Oxycodone I
- Oxycodone II
- Propoxyphene
- Creatinine
| Description |
Size |
Catalogue Number |
| Drugs Of Abuse Array II (Urine) Controls |
2 x 4 x 1 ml |
EV3657 |
| Drugs Of Abuse Array II (Whole Blood) Controls |
2 x 4 x 1 ml |
EV3682 |
| Drugs Of Abuse Array II (Oral Fluid) Controls |
2 x 4 x 1 ml |
EV3702 |
Drugs of Abuse Array III Controls
Assayed control for use in monitoring the accuracy and precision of the analytes above on Randox Biochip systems. Two levels of control are provided covering the cut-off range.
- Lyophilised for enhanced stability
- Stable to expiry date at +2-8°C
- Reconstituted stability of 7 days at +2-8°C
Analytes
- Chloral Hydrate Metabolite
- Ethyl Glucuronide
- Fentanyl
- Ketamine Metabolite
- Meperidine
- Meprobamate
- Zaleplon
- Zolpidem
- Zopiclone
- 7-amino Flunitrazepam
- Creatinine
| Description |
Size |
Catalogue Number |
| Drugs of Abuse Array III (Whole Blood) Control |
4 x 2 x 1 ml |
EV3794 |
Drugs of Abuse Array IV Controls
Assayed control for use in monitoring the accuracy and precision of the analytes above on Randox Biochip systems. Two levels of control are provided covering the cut-off range.
- Lyophilised for enhanced stability
- Stable to expiry date at +2-8°C
- Reconstituted stability of 7 days at +2-8°C
Analytes
- Acetaminophen
- Dextromethorphan
- Escitalopram
- Fluoxetine
- Haloperidol
- Ibuprofen
- Methylphenidate
- Salicylate
- Salicyluric Acid
- Sertraline
- Tramadol
- Trazodone
- Tricyclic Antidepressants
- Creatinine
| Description |
Size |
Catalogue Number |
| Drugs of Abuse Array IV (Whole Blood) Control |
4 x 2 x 1 ml |
EV3809 |
Drugs of Abuse Array V Controls
Assayed control for use in monitoring the accuracy and precision of the analytes above on Randox Biochip systems. Two levels of control are provided covering the cut-off range.
- Lyophilised for enhanced stability
- Stable to expiry date at +2-8°C
- Reconstituted stability of 7 days at +2-8°C
Analytes
- Bath Salts 1 (Methcathinone and Mephedrone)
- Bath Salts 2 (MDPV)
- Benzylpipernzines
- Mescaline
- Phenylpiperazines
- Salvinorin
- Synthetic Cannabinoids 1
- Synthetic Cannabinoids 2
- Synthetic Cannabinoids 3
- Synthetic Cannabinoids 4
| Description |
Size |
Catalogue Number |
| Drugs of Abuse Array V (Urine) Control |
4 x 2 x 1 ml |
EV3814 |
|