RX suzuka - Specifications
Contact Randox

View Brochure:

 

Physical Dimensions

Height 1150 mm/45.28 inches

Depth 800 mm/31.5 inches

Length 1260 mm/49.6 inches

Weight 400kg/881.85 lbs

 

Performance Characteristics

Analyser Type Fully automated random access clinical analyser with STAT priority

Throughput 800 tests/hour or up to 1200 tests/hour with ISE

Assay Types End-point, kinetic, fixed rate, bichromatic, turbidimetric and ISE

Test Channels 44 photometric tests and 3 ISEs can be performed at the same time

 

Sample Unit

Sample Capacity Double sample carousel with 140 sample positions including 80 routine sample positions, 10 STAT, 39 calibrator, 8 QC and 3 wash positions

Sample Cooling Continuous cooling of QC carousel 5-15oC

Sample Tubes Supports various size sample tubes; specification: (12 - 16mm) x (25 - 100mm)

Sample Identification Barcode sample identification code 128, code 39

Sample Volume 2µl - 35µl (0.1µl stepping)

Sampling Technology Liquid level detection, clot detection and collision detection

Automatic Sample Dilution Pre-dilution and automatic re-assay with diluted, reduced or increased sample volume. 3 - 170 times

Sample Probe Dedicated sample probe with liquid level sensor, crash detection, bubble detection and clot detection. High pressure rinsing of the internal wall and stream washing of external wall.

Sample Type Serum, Plasma, Urine, CSF and Supernatant

Sample Addition Sampling interruption for addition of samples

Reagent Unit

Reagent Probe Dedicated twin reagent probes with liquid level sensor and crash detection. High pressure rinsing of the internal wall and stream washing of external wall.

Reagent Volume 20µl - 350µl (0.1µl stepping)

Reagent Capacity Double reagent carousel with 90 reagent positions suitable for 70ml and 20ml reagent bottles.

Reagent Cooling Continuous cooling between 5-15oC

Reagent Identification Automatic barcode reagent identification. Code 128

Reagent Inventory Calculation of remaining reagent volume and number of tests available. Alerts for reagent shortage to ensure continuous analysis.

 

Reaction System

Reaction Cuvette 160 reusable plastic cuvettes, 5mm path length, 12 step cuvette washing system

Total Reaction Volume 120µl - 450µl

Reaction Temperature 37oC ±0.1oC

Reaction Time 10, 22 minutes

Reaction Disk Temperature Circulating Water

Mixing Dual flat paddle stirrers

Water Consumption less than 30 litres per hour consumed at peak use

Wastewater Treatment Two diffluence for high and low concentration wastewater. With the function of concentrated waste liquid level alarming

 

Optical System

Light Source 20W/12V halogen lamp with 2000 hours use

Photometer Diffraction Grating Photometry

Detection Principle 12 wavelengths: 340nm, 380nm, 405nm, 450nm, 505nm, 546nm, 570nm, 600nm, 660nm, 700nm, 750nm and 800nm

Wavelength Precision ±2nm

OD Linear Range 0 - 3.3 Abs

 

Calibration and QC

Calibration 1 point linear method, 2 point linear method, multiple point linear method, non linear method, 9 types of calibration curve, Up to 6 calibrators per test

Calibration Tracking Automatically depicts K-value trends

Data Management Real-time and monthly QC data archiving, Automatic plotting of Levy-Jennings charts, Alarms when control results out of range, Record reason for discrepant results

 

Operating System

PC Operating System Windows XP

Software English version graphical operating software

Software Functions Automatic calibration, Automatic barcode scanning, Reagent information management, Serum index, Reaction process monitoring, Dirty cup memory evading, Cross contamination prevention, Patient information memory and association input, Automatic report audit, Report format statistic and printing, Reference range classification, Alarming information classification, Automatic dormancy and start up, Real time online help

Report Printing Report formats support the user-defined mode

PC configuration CPU ≥2.2 GHz (dual-core processor); Memory ≥1G; Hard disk ≥ 160G; 17 inch LCD display; Stylus, inkjet, laser printer (optional)

System connection TCP/IP network interface, standard RS-232C interface

Connectivity Connect with LIS/HIS system

 

Power Requirements

Input Voltage Voltage AC 220V ± 22V

Power Consumption 2500 VA, 50Hz ± 1Hz

 

Catalogue No./ Ordering Info

RX suzuka analyser RX8002

Products

Toxicology

Contract Manufacturing

Randox Engineering
Other Randox Websites

Randox Food Diagnostics
Randox Toxicology
Randox Life Sciences
Randox Health Checks
Randox Online Store
Randox Pharma Services
Randox Testing Services
Drugs of Abuse Testing
RIQAS
Lab Test Blog


Follow us on facebook Follow us on twitter Linked In You Tube

Accreditation