Toxicology Control Calibrators

Home - Quality Control - Toxicology Control Calibrators
acusera-qc-logo

Benzodiazepine Calibrator Set

Dedicated Benzodiazepine calibrator designed for use with the Randox Oxazepam assay. Five levels are provided in a convenient liquid ready-to-use format.

Features & Benefits

  • Liquid ready-to-use
  • 100% human urine
  • Stable to expiry date at 2°C – 8°C
  • Open vial stability of 28 days at 2°C – 8°C
Benzodiazepine Control and CalibratorSizeAnalytesCat No 
Benzodiazepine Calibrator Set5 x 10ml1DA3129

Analytes

  • Oxazepam

Cannabinoid Calibrator Set

Dedicated Cannabinoid calibrator designed for use with the Randox Cannabinoid assay. Five levels are provided in a convenient liquid ready-to-use format.

Features & Benefits

  • Liquid ready-to-use
  • 100% human urine
  • Stable to expiry date at 2°C – 8°C
  • Open vial stability of 28 days at 2°C – 8°C
DescriptionSizeAnalytesCat No 
Cannabinoid Calibrator Set5 x 3ml1DA2700

Analytes

  • 11-nor-Δ9-THC-9-COOH

Drugs of Abuse Array I Plus Calibrator

Multi-analyte calibrator designed for use with the Drugs of Abuse Array I Plus.

Features & Benefits

  • Lyophilised for enhanced stability
  • Stable to expiry date at 2oC – 8oC
  • Urine- Reconstituted stability of 14 days at 2oC – 8oC
  • Whole Blood – Reconstituted stability of 7 days at 2oC – 8oC or 14 days at -20oC
DescriptionSizeAnalytesCat No 
Drugs of Abuse Assay I Plus (Urine) Calibrators9 x 1ml14EV3744
Drugs of Abuse Assay I Plus (Whole Blood) Calibrators9 x 1ml14EV3749

Analytes

  • Amphetamine
  • Barbiturates
  • Benzodiazepine 1
  • Benzodiazepine 2
  • Buprenorphine
  • Cannabinoids
  • Cocaine Metabolite
  • MDMA
  • Methadone
  • Methamphetamine
  • Opiates
  • Phencyclidine
  • Tricyclic Antidepressants
  • Creatinine

Drugs of Abuse Array II Calibrators

Dedicated calibrator designed for use the Drugs of Abuse Array II control.

Features & Benefits

  • Lyophilised for enhanced stability
  • Stable to expiry at 2oC – 8oC
  • Urine- Reconstituted stability of 7 days at 2oC – 8oC or 28 days at -20oC
  • Whole Blood – Reconstituted stability of 7 days at 2oC – 8oC or 28 days at -20oC
DescriptionSizeAnalytesCat No 
Drugs of Abuse Array II (Urine) Calibrator Series9 x 1ml11EV3656
Drugs of Abuse Array II (Whole Blood) Calibrator Series9 x 1ml11EV3687
Drugs of Abuse Array II (Oral Fluid) Calibrator Series9 x 1ml11EV3701

Analytes

  • 3,4 Methylenedioxymethamphetamine (MDMA)
  • Ketamine
  • Lysergic Acid Diethylamide (LSD)
  • Methaqualone
  • Buprenorphine
  • Fentanyl
  • Generic Opioids
  • Oxycodone I
  • Oxycodone II
  • Propoxyphene
  • Creatinine

Drugs of Abuse Array III Calibrators

Multi-analyte calibrator designed for use with the Drugs of Abuse Array III control.

Features & Benefits

  • Lyophilised for enhanced stability/li>
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 7 days at 2°C – 8°C
DescriptionSizeAnalytesCat No 
Drugs of Abuse Array III (Urine) Calibrator Series9 x 1ml11EV3829
Drugs of Abuse Array III (Whole Blood) Calibrator Series9 x 1ml11EV3797

Analytes

  • Chloral Hydrate Metabolite
  • Ethyl Glucuronide
  • Fentanyl
  • Ketamine Metabolite
  • Meperidine
  • Meprobamate
  • Zaleplon
  • Zolpidem
  • Zopiclone
  • 7-amino Flunitrazepam
  • Creatinine

Drugs of Abuse Array IV Calibrator

Multi-analyte calibrator designed for use with the Drugs of Abuse Array IV control.

Features & Benefits

  • Lyophilised for enhanced stability
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 7 days at 2°C – 8°C
DescriptionSizeAnalytesCat No 
Drugs of Abuse Array IV (Urine) Calibrator9 x 1ml14EV3834
Drugs of Abuse Array IV (Whole Blood) Calibrator9 x 1ml14EV3808

Analytes

  • Acetaminophen
  • Dextromethorphan
  • Escitalopram
  • Fluoxetine
  • Haloperidol
  • Ibuprofen
  • Methylphenidate
  • Salicylate
  • Salicyluric Acid
  • Sertraline
  • Tramadol
  • Trazodone
  • Tricyclic Antidepressants
  • Creatinine

Drugs of Abuse Array V Calibrators

Multi-analyte calibrator designed for use with the Drugs of Abuse Array V control.

Features & Benefits

  • Lyophilised for enhanced stability
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 7 days at 2°C – 8°C
DescriptionSizeAnalytesCat No 
Drugs of Abuse Array V (Urine) Calibrator Series9 x 1ml10EV3815
Drugs of Abuse Array V (Whole Blood) Calibrator Series9 x 1ml10EV3847

Analytes

  • Bath Salts 1 (Methcathinone and Mephedrone)
  • Bath Salts 2 (MDPV)
  • Benzylpiperazines
  • Mescaline
  • Phenylpiperazines
  • Salvinorin
  • Synthetic Cannabinoids 1
  • Synthetic Cannabinoids 2
  • Synthetic Cannabinoids 3
  • Synthetic Cannabinoids 4

Ecstasy Calibrator Set

Dedicated Ecstasy calibrator designed for use with the Randox Ecstasy assay. Five levels are provided in a convenient liquid ready-to-use format.

Features & Benefits

  • Liquid ready-to-use
  • Human urine
  • Stable to expiry date at 2°C – 8°C
  • Open vial stability of 28 days at 2°C – 8°C
DescriptionSizeAnalytesCat No 
Ecstasy Calibrator Set5 x 10ml1DA2701

Analytes

  • MDMA

EDDP Calibrator Set

Dedicated EDDP calibrator designed for use with the Randox EDDP assay. Five levels are provided in a convenient liquid ready-to-use format.

Features & Benefits

  • Liquid ready-to-use
  • Human urine
  • Stable to expiry date at 2°C – 8°C
  • Once opened stable to expiry date at 2°C – 8°C
DescriptionSizeAnalytesCat No 
EDDP Calibrator Set5 x 10ml1DA2702

Analytes

  • Methadone Metabolite (EDDP)

Ethanol Calibrator and Control Set

Dedicated Ethanol calibrator and control designed for use with the Randox Ethanol assay. Two levels of each our control and calibrator are provided in a convenient liquid ready-to-use format.

Features & Benefits

  • Liquid ready-to-use
  • Human urine
  • Stable to expiry date at 2°C – 8°C
  • Open vial stability of 28 days at 2°C – 8°C
DescriptionSizeAnalytesCat No 
Ethanol Control/Calibrator Set5 x 10 ml1DA2703

Analytes

  • Ethanol

Multidrug Calibrator Set

Multi-analyte calibrator designed for use with the Randox Amphetamines, Barbiturates, Opiates, cocaine and Methadone assays. 5 levels are provided in a convenient liquid ready-to-use format.

Features & Benefits

  • Liquid ready-to-use
  • Human urine
  • Stable to expiry date at 2°C – 8°C
  • Open vial stability of 28 days at 2°C – 8°C
DescriptionSizeAnalytesCat No 
Multidrug Calibrator Set5 x 10ml5DA2704

Analytes

  • Benzoylecgonine (Cocaine)
  • Methadone
  • Secobarbital
  • Methamphetamine
  • Morphine (Opiates)

    Laboratory Quality Control

Request a meeting
×
Make an Enquiry - RX series
×
Make an Enquiry - Reagents
  • This field is for validation purposes and should be left unchanged.
×
Kit Insert Request - Reagents
×
Kit Insert Request - Reagents
×
Make an Enquiry - Reagents
×
Make an Enquiry - Quality Control
×
Make an Enquiry - RIQAS
×
Make an Enquiry - RIQAS
×
Make an Enquiry - Quality Control
×
Make an Enquiry
×
Make an Enquiry - Biochip
  • This field is for validation purposes and should be left unchanged.
×
Make an Enquiry - Molecular
  • This field is for validation purposes and should be left unchanged.
×
Make an Enquiry - Future Diagnostics
×
Make an Enquiry - RX series (Product)
×
Make an Enquiry - Quality Control
×
Make an Enquiry - RIQAS
×
Make an Enquiry - Reagents
×
Por favor, introduzca sus datos para ver nuestro último seminario
×