Superoxide Dismutase (Ransod) Quality Control

Home - assayed - Page 7

Superoxide Dismutase (Ransod) Quality Control

Therapeutic Drug Quality Control

A dedicated Superoxide Dismutase control for use in the routine monitoring of the Randox Ransod assay on clinical chemistry analysers.

Features & Benefits

  • Lyophilised for enhanced stability
  • Bovine based whole blood
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 10 days at 2°C – 8°C
DescriptionSizeAnalytesCat No
Ransod (superoxide dismutase)10 x 1 ml1SD126

Analytes

  • Superoxide Dismutase

Glutathione Peroxidase (Ransel) Quality Control

Therapeutic Drug Quality Control

A dedicated Glutathione Peroxidase control for use in the routine monitoring of the Randox Ransel assay on clinical chemistry analysers.

Features & Benefits

  • Lyophilised for enhanced stability
  • Bovine based whole blood
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 3 days at 2°C – 8°C
DescriptionSizeAnalytesCat No
Ransel (glutathione peroxidase) control10 x 1 ml1SC692

Analytes

  • Glutathione Peroxidase

Glutathione Reductase Quality Control

Therapeutic Drug Quality Control

A dedicated Glutathione Reductase control for use in the routine monitoring of the Randox Glutathione Reductase assay on clinical chemistry analysers.

Features & Benefits

  • Lyophilised for enhanced stability
  • Bovine based serum
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 1 day at 2°C – 8°C or 8 hours at 15°C – 25°C
DescriptionSizeAnalytesCat No
Glutathione Reductase Control10 x 5ml1GR2608

Analytes

  • Glutathione Reductase

Blood Gas Quality Controls

Therapeutic Drug Quality Control

The Randox Acusera Blood Gas Quality Controls contain assayed target values for ten parameters, covering pH, pCO2, pO2, electrolytes, glucose and lactate. The material is provided in easy to open ampoules for added convenience and ease-of-use. The liquid ready-to-use nature of the control makes it ideal for use in point-of-care testing and on a wide range of blood gas instruments.

 

Features & Benefits

  • Liquid ready-to-use
  • Aqueous material
  • Method specific target values provided for the most common blood gas analysers
  • Suitable for use in POC testing
  • Stable to expiry date at 2°C – 8°C
  • Once opened controls should be analysed immediately for pH and blood gas parameters, for electrolyte measurements the control should be analysed within 1 hour of opening
DescriptionSizeAnalytesCat No
Blood Gas Control Level 130 x 1.8ml10BG5001
Blood Gas Control Level 230 x 1.8ml10BG5002
Blood Gas Control Level 330 x 1.8ml10BG5003

Analytes

  • pCO2
  • pO2
  • Calcium
  • Glucose
  • Potassium
  • pH
  • Bicarbonate
  • Chloride
  • Lactate
  • Sodium

Related Products


Haematology Quality Control

Therapeutic Drug Quality Control

Combining 45 analytes in total the Randox Acusera Haematology quality control completely covers the commonly tested full blood profile in a single control. Providing a true third party solution for Sysmex and Mindray haematology analysers with 5-part differential technology an unbiased, independent assessment of analytical performance is guaranteed.

Features & Benefits

  • Liquid ready-to-use
  • 100% Human whole blood
  • Barcoded labels enabling quick and easy sample recognition
  • Stable for 70 days at 2ºC to 8°C
  • Open vial stability of 14 days at 2ºC to 8°C
DescriptionSizeAnalytesCat No
Haematology Tri-Level3 x 2 x 4.5 ml45HM5162

Analytes

  • Basophils (BASO)*
  • % Basophils (% BASO)
  • BASO-X
  • BASO –Y
  • DIFF-X
  • DIFF-Y
  • Eosinophils (EOS)
  • % Eosinophils (%EOS)
  • FSC-X
  • Haematocrit (HCT)
  • Haemoglobin (HGB)
  • Haemopioetic Progenitor Cell (HPC)
  • IMIDC
  • IMIRF
  • Immature Granulocytes (IG)
  • % Immature Granulocytes (%IG)
  • Immature Myeloid Information (IMI)
  • Immature Platelet Fraction (IPF)
  • Lymphocytes (LYMPH)
  • % Lymphocytes (% LYMPH)
  • Mean Corpuscular Volume (MCV)
  • Mean Corpuscular Haemoglobin (MCH)
  • Mean Corpuscular Haemoglobin Concentration (MCHC)
  • Mean Platelet Volume (MPV)
  • Monocytes (MONO)
  • % Monocytes (% MONO)
  • Neutrophils (NEUT)
  • % Neutrophils (% NEUT)
  • Nucleated Red Blood Cells X (NRBC-X)
  • Nucleated Red Blood Cells Y (NRBC-Y)
  • Nucleated Red Blood Cells (NRBC)*
  • % Nucleated Red Blood Cells (%NRBC)
  • Platelet Distribution Width (PDW)
  • Platelet Large Cell Ratio (P-LCR)
  • Plateletcrit (PCT)
  • Platelets (PLT)
  • Platelets Optical Count (PLT-0)
    • Red Blood Cells (RBC)

    • Red Blood Cell X (RBC-X)
    • Red Blood Cell Y (RBC-Y)
    • Red Blood Cell Distribution Width CV (RDW-CV)
    • Red Blood Cell Distribution Width SD (RDW-SD)
    • Red Blood Cells Optical Count (RBC-O)
    • White Blood Cells (WBC)
    • White Blood Cells Differential (WBC-D)

    *This product may not be suitable for the control of NRBC# and Basophils on some Sysmex models


    Coagulation Quality Control

    Therapeutic Drug Quality Control

    The Randox Acusera Coagulation Quality Control covers 16 analytes in total including a wide variety of factor assays, basic coagulation and thrombophilia parameters. As an assayed control instrument and method specific target values and ranges are provided.

    Features & Benefits

    • Lyophilised for enhanced stability
    • 100% human plasma
    • Assayed target values provided for 16 analytes
    • Stable to expiry date at 2°C – 8°C
    • Reconstituted stability of up to 24 hours at 2°C – 8°C
    DescriptionSizeAnalytesCat No
    Coagulation Control Level 112 x 1ml16CG5021
    Coagulation Control level 212 x 1ml16CG5022
    Coagulation Control Level 312 x 1ml16CG5023

    Analytes

    • Prothrombin Time
    • Activated Partial Thromboplastin Time
    • Thrombin Time
    • Fibrinogen
    • Antithrombin III
    • Factor II
    • Factor V
    • Factor VII
    • Factor VIII
    • Factor IX
    • Factor X
    • Factor XI
    • Factor XII
    • Plasminogen
    • Protein C
    • Protein S