Assayed Chemistry Premium Plus Quality Control

Home - Laboratory - Page 13

Assayed Chemistry Premium Plus Quality Control

Therapeutic Drug Quality Control

The Randox Acusera Assayed Chemistry Premium Plus Control is designed to monitor both accuracy and precision of routine chemistry assays. As a true third party control assayed instrument and method specific target values are provided for 66 analytes including a wide range of lipids, cardiac markers, therapeutic drugs, immunoassays, proteins, routine chemistries and trace metals. Electrophoresis targets are also provided as a percentage breakdown of total protein.

Features & Benefits

  • Lyophilised for enhanced stability
  • Human based serum
  • Typical Osmolality values: Level 2 is 300 mOsm/kg, Level 3 is 370 mOsm/kg
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of up to 7 days at 2°C – 8°C or 4 weeks at -20°C
DescriptionSizeAnalytesCat No
Assayed Chemistry Premium Plus Level 220 x 5ml66HN1530
Assayed Chemistry Premium Plus Level 320 x 5ml66HE1532
Assayed Chemistry Premium Plus Level 2 and 32 x 5 x 5ml66HS2611

Analytes

  • Alpha-1-Globulin (Electrophoresis)
  • Alpha-2-Globulin (Electrophoresis)
  • Alpha-HBDH
  • Acid Phosphatase (Total)
  • Albumin
  • Albumin (Electrophoresis)
  • Alkaline Phosphatase
  • ALT
  • Amylase Pancreatic
  • Amylase Total
  • Apolipoprotein A-1
  • Apolipoprotein B
  • AST
  • Beta-1-Globulin (Electrophoresis)
  • Bicarbonate
  • Bile Acids
  • Bilirubin Direct
  • Bilirubin Total
  • Calcium
  • Chloride
  • Cholesterol
  • Cholinesterase
  • CK Total
  • Copper
  • Cortisol
  • Creatinine
  • D-3-Hydroxybutyrate
  • Digoxin
  • Folate
  • Free T4
  • Gamma-Globulin (Electrophoresis)
  • Gentamicin
  • Gamma-GT
  • GLDH
  • Glucose
  • HDL Cholesterol
  • Immunoglobulin A
  • Immunoglobulin G
  • Immunoglobulin M
  • Iron
  • Iron (TIBC)
  • Lactate
  • LDH
  • Lipase

 

 

  • Lithium
  • Magnesium
  • NEFA
  • Osmolality
  • Paracetamol
  • Phosphate Inorganic
  • Potassium
  • Protein Total
  • PSA Total
  • Salicylate
  • Sodium
  • Theophylline
  • Thyroid Stimulating Hormone
  • Tobramycin
  • Total T3
  • Total T4
  • Transferrin
  • Triglycerides
  • Urea
  • Uric Acid
  • Vitamin B12
  • Zinc

CK-MB Quality Control

Therapeutic Drug Quality Control

The Randox Acusera dedicated CK-MB control is designed for use in the routine monitoring of both accuracy and precision. Accurately assigned target values and ranges are provided for both serum start, substrate start and CK-NAC methods.

Features & Benefits

  • Lyophilised for enhanced stability
  • 100% human serum
  • Assayed target values provided for 2 cardiac markers
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 5 days at 2ºC to 8ºC, , 8 hours at +25ºC and 28 days at -20ºC
DescriptionSizeAnalytesCat No
CK-MB Control10 x 2ml2CK1212

Analytes

  • CK-MB
  • CK-NAC

Related Products


Cardiac Quality Control

Therapeutic Drug Quality Control

The Randox Acusera Tri-Level Cardiac Quality Control is designed for use in the routine monitoring of both accuracy and precision. Assayed instrument and method specific target values are provided for 7 cardiac markers along with temperature specific target values for CK and CK-MB.

Features & Benefits

  • Lyophilised for enhanced stability
  • Human based serum
  • Assayed target values provided for 7 cardiac markers
  • Cut off levels for Troponin I and T in line with internationally recommended levels
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 5 days at 2°C – 8°C or 4 weeks at -20°C
DescriptionSizeAnalytesCat No
Tri-Level Cardiac Control3 x 1ml7CQ3100
Tri-Level Cardiac Control3 x 2ml7CQ3259

Analytes

  • CK Total
  • CK-MB (Mass)
  • Myoglobin
  • Troponin T
  • CK-MB (Activity)
  • Homocysteine
  • Troponin I

Related Products


Total Antioxidant Status Quality Control

Therapeutic Drug Quality Control

Dedicated control for use in the routine monitoring of the Randox Total Antioxidant Status assay on clinical chemistry analysers

Features & Benefits

  • Lyophilised for enhanced stability
  • Bovine based serum
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 2 days at 2°C – 8°C or 12 hours at 15°C – 25°C
DescriptionSizeAnalytesCat No
Total Antioxidant Status Control10 x 5 ml1NX2331

Analytes

  • Total Antioxidant Status

Superoxide Dismutase (Ransod) Quality Control

Therapeutic Drug Quality Control

A dedicated Superoxide Dismutase control for use in the routine monitoring of the Randox Ransod assay on clinical chemistry analysers.

Features & Benefits

  • Lyophilised for enhanced stability
  • Bovine based whole blood
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 10 days at 2°C – 8°C
DescriptionSizeAnalytesCat No
Ransod (superoxide dismutase)10 x 1 ml1SD126

Analytes

  • Superoxide Dismutase

Glutathione Peroxidase (Ransel) Quality Control

Therapeutic Drug Quality Control

A dedicated Glutathione Peroxidase control for use in the routine monitoring of the Randox Ransel assay on clinical chemistry analysers.

Features & Benefits

  • Lyophilised for enhanced stability
  • Bovine based whole blood
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 3 days at 2°C – 8°C
DescriptionSizeAnalytesCat No
Ransel (glutathione peroxidase) control10 x 1 ml1SC692

Analytes

  • Glutathione Peroxidase

Glutathione Reductase Quality Control

Therapeutic Drug Quality Control

A dedicated Glutathione Reductase control for use in the routine monitoring of the Randox Glutathione Reductase assay on clinical chemistry analysers.

Features & Benefits

  • Lyophilised for enhanced stability
  • Bovine based serum
  • Stable to expiry date at 2°C – 8°C
  • Reconstituted stability of 1 day at 2°C – 8°C or 8 hours at 15°C – 25°C
DescriptionSizeAnalytesCat No
Glutathione Reductase Control10 x 5ml1GR2608

Analytes

  • Glutathione Reductase

Blood Gas Quality Controls

Therapeutic Drug Quality Control

The Randox Acusera Blood Gas Quality Controls contain assayed target values for ten parameters, covering pH, pCO2, pO2, electrolytes, glucose and lactate. The material is provided in easy to open ampoules for added convenience and ease-of-use. The liquid ready-to-use nature of the control makes it ideal for use in point-of-care testing and on a wide range of blood gas instruments.

 

Features & Benefits

  • Liquid ready-to-use
  • Aqueous material
  • Method specific target values provided for the most common blood gas analysers
  • Suitable for use in POC testing
  • Stable to expiry date at 2°C – 8°C
  • Once opened controls should be analysed immediately for pH and blood gas parameters, for electrolyte measurements the control should be analysed within 1 hour of opening
DescriptionSizeAnalytesCat No
Blood Gas Control Level 130 x 1.8ml10BG5001
Blood Gas Control Level 230 x 1.8ml10BG5002
Blood Gas Control Level 330 x 1.8ml10BG5003

Analytes

  • pCO2
  • pO2
  • Calcium
  • Glucose
  • Potassium
  • pH
  • Bicarbonate
  • Chloride
  • Lactate
  • Sodium

Related Products


Lipid Quality Controls

acusera-qc-logo

Our Acusera Lipid Quality Controls have been manufactured from 100% human serum to ensure they are commutable, mirroring the behaviour of a real patient sample, with minimal lot to lot value shifts. As all of our lipid quality controls are lyophilised, they contain no stabilisers or preservatives which are known to affect the overall performance of the controls. The multi-analyte controls enable test menu consolidation which, along with the four year shelf life from the date of manufacture, ensures minimal waste helping your lab reduce costs.

Lyophilised Lipid Quality Controls

Lipid Control

7 Analytes

Apoplipoprotein Control

4 Analytes

Lipoprotein (a) Control

1 Analyte

sdLDL Control

1 Analyte

 


Haematology Quality Control

Therapeutic Drug Quality Control

Combining 45 analytes in total the Randox Acusera Haematology quality control completely covers the commonly tested full blood profile in a single control. Providing a true third party solution for Sysmex and Mindray haematology analysers with 5-part differential technology an unbiased, independent assessment of analytical performance is guaranteed.

Features & Benefits

  • Liquid ready-to-use
  • 100% Human whole blood
  • Barcoded labels enabling quick and easy sample recognition
  • Stable for 70 days at 2ºC to 8°C
  • Open vial stability of 14 days at 2ºC to 8°C
DescriptionSizeAnalytesCat No
Haematology Tri-Level3 x 2 x 4.5 ml45HM5162

Analytes

  • Basophils (BASO)*
  • % Basophils (% BASO)
  • BASO-X
  • BASO –Y
  • DIFF-X
  • DIFF-Y
  • Eosinophils (EOS)
  • % Eosinophils (%EOS)
  • FSC-X
  • Haematocrit (HCT)
  • Haemoglobin (HGB)
  • Haemopioetic Progenitor Cell (HPC)
  • IMIDC
  • IMIRF
  • Immature Granulocytes (IG)
  • % Immature Granulocytes (%IG)
  • Immature Myeloid Information (IMI)
  • Immature Platelet Fraction (IPF)
  • Lymphocytes (LYMPH)
  • % Lymphocytes (% LYMPH)
  • Mean Corpuscular Volume (MCV)
  • Mean Corpuscular Haemoglobin (MCH)
  • Mean Corpuscular Haemoglobin Concentration (MCHC)
  • Mean Platelet Volume (MPV)
  • Monocytes (MONO)
  • % Monocytes (% MONO)
  • Neutrophils (NEUT)
  • % Neutrophils (% NEUT)
  • Nucleated Red Blood Cells X (NRBC-X)
  • Nucleated Red Blood Cells Y (NRBC-Y)
  • Nucleated Red Blood Cells (NRBC)*
  • % Nucleated Red Blood Cells (%NRBC)
  • Platelet Distribution Width (PDW)
  • Platelet Large Cell Ratio (P-LCR)
  • Plateletcrit (PCT)
  • Platelets (PLT)
  • Platelets Optical Count (PLT-0)
    • Red Blood Cells (RBC)

    • Red Blood Cell X (RBC-X)
    • Red Blood Cell Y (RBC-Y)
    • Red Blood Cell Distribution Width CV (RDW-CV)
    • Red Blood Cell Distribution Width SD (RDW-SD)
    • Red Blood Cells Optical Count (RBC-O)
    • White Blood Cells (WBC)
    • White Blood Cells Differential (WBC-D)

    *This product may not be suitable for the control of NRBC# and Basophils on some Sysmex models