Researching the Evidence Investigator
The Evidence Investigator analyser is based on the award-winning Biochip Array Technology (BAT). Biochip Array Technology is a multi-analyte testing platform allowing the simultaneous quantitative or qualitative detection of a wide range of analytes from a single sample.
The Evidence Investigator is a semi-automated benchtop analyser which is tailored for the areas of research, forensic, clinical, molecular and veterinary testing. The key feature is the fast turn-around time the Evidence Investigator can process up to 44 results from a single sample, with a maximum throughput of up to 2375 tests per hour. The Evidence Investigator saves time because it will carry out multiplex testing which will allow multiple tests to be carried out from a single patient sample which in return will save time and resources. The machine is more suitable for medium throughput laboratories.
The technology offers a wide-ranging and diverse test menu which will benefit the research areas immunology, metabolic, Sport & Exercise, oncology and cardiovascular. Randox Research provides the Evidence Investigator to the five research areas to help their research become more efficient, cost effective and accurate.
Randox works extremely hard with their research and development, over 16% of turnover is reinvested in R&D. The current collaboration Randox works along with are Royal Victoria Hospital, Queen’s University Belfast and Cambridge University.
Randox Biosciences are dedicated to assisting research projects to completion and will make available the technology to ensure the universities receive highly accurate results for their research. Randox creates their products in-house therefore provides the flexibility of the research project. Randox can provide the university a full range of arrays, biomarkers and analysers to meet their requirements of the research.
Within Cardiovascular Research, Randox offer a comprehensive menu of cytokines. The combination of highly specific antibodies and advanced chemistries enables cytokines, cytokine receptors and growth factors to be detected simultaneously in a single sample, providing valuable information relating to each cytokine under test and possible associations between cytokines in each sample which will benefit the research. Randox offer excellent tools for universities and hospitals researchers such as routine and novel assays and can provide research analysers such as the Evidence Investigator which is suitable for medium sized laboratory.
Oncology Research has 20 biomarkers that can be custom-made to be used on the Biochip. Randox Biosciences offers a wide and extensive test menu to researchers to enable the specific product tailored to meet their clinical trail requirements.
Metabolic & Nutrition Research is another area Randox offers a wide-ranging range of tests specifically directed to Metabolic and Nutrition Research. Randox offers reagents and arrays on the award-winning Biochip Array Technology.
For more information on our Research areas and the tests that we can provide, contact us at – Info@RandoxBiosciences.com
The key features and benefits of Biochip Array Technology
Biochip Array Technology
In 1992, Randox invested £180 million to create and introduce Biochip Array Technology (BAT) which converted laboratory testing. Randox came up with the innovation by recognising the major problem with traditional diagnosis. Within traditional diagnosis several tests are typically required which involves multiple blood draws from the patient, many visits to the hospital, increased reagent volume and increased time to diagnosis. Biochip Array Technology allows for the simultaneous quantitative or qualitative detection of a wide range of analytes from one single sample. Therefore, it is faster, cost saving and more effective leading to better clinical decisions. Today the technology (BAT) is used in countless laboratories worldwide and a range of three biochip analysers are now offered.
The main basis of the Biochip Array Technology
- 9x9mm biochip which acts as a solid phase reaction vessel.
- Each of the biochips are pre-coated with an array of discrete test regions (DTRs)
- One biochip per sample used to generate multiple results.
- Randox Biochips hold up to 49 tests.
- Based on chemiluminescent signal emitting light, without heat which results a chemical reaction.
The key features and benefits of the Biochip Array Technology
Highly accurate testing
- The biochip array technology provides high standard of accurate test results with CV’s <10%
- Multiplex analysis minimises analytical variation between the tests.
Better diagnosis
- Increased patient information available through testing multiple markers
- Patients receive their results quicker compared to the traditional diagnosis.
Reduced sample volume
- Reduced sample required therefore patients feel more at ease.
Wide test menu
- Wide test menu provides a variety for clients and allows flexibility.
Multiple samples
- Multiple samples can be used on BAT which include the following; serum, plasma, whole blood, urine and many others which allows for flexibility in their testing
Cost consolidation
– The process reduces the amount of time spent on individual tests and associated laboratory costs
Biochip testing platforms
Evidence Evolution
The Evidence Evolution is fully automated random-access biochip testing platform. The machine allows any test to perform at any time as it is a highly versatile analyser which can operate any workflow. It can receive 2640 tests per hour which means the machine has a fast turnaround time. As well as this, it allows multiple tests to be performed from a single sample which reduces time and resources spent on individual tests. The Evidence Evolution can be tailored to certain laboratory needs and have features including automatic start-up and shut down, relaxed testing capability and traceability of biochips. The equipment overall is made to be easy for the client to use as it includes customisable user settings and easy to follow result screens giving them the fast and accurate operations they would prefer.
Evidence
The Evidence Analyser is the protein Biochip Array technology. Like the Evidence Evolution it is fully automated which is suitable for busy laboratories, hospitals, forensic and clinical toxicology. The machine is floor standing and can receive up to 3690 per hour. The machine has features such as easy to follow software and customisable user settings which gives laboratories the opportunity to receive fast and accurate results.
Evidence investigator
The Evidence Investigator is often used for research, clinical, forensic, molecular and veterinary testing. The machine is semi-automated and can combine immunoassay and molecular diagnostics on a single platform with protein and DNA biochips. This machine also has a quick turnaround time with the ability to achieve 2376 tests per hour with 44 analytes screened per biochip. The evidence investigator provides more tests on the test menu which allows variety.
Evidence MultiSTAT
The final platform is the Evidence MultiSTAT. The Evidence MultiSTAT is a fully-automated analyser which provides quality results. It is a simple and easy to use analyser which requires minimal training with only three steps to complete the process. The machine can provide multiplex testing yields up to 46 results in under ten minutes. It is ease-of-use for non-laboratory staff and provides full traceability of user action with password controlled software.
For more information on our Biochip Array Technology contact the Randox Biosciences team by emailing info@Randoxbiosciences.com
Evidence Series ā Investigator and Molecular testing
Evidence Investigator | Adaptable, Efficient & Comprehensive
The Evidence Investigator is a compact, semi-automated benchtop analyser that offers efficient and comprehensive testing across a range of applications including clinical diagnostics, molecular, research, toxicology and food diagnostics.
Renowned for its versatility, robustness and effective reporting methods, the Evidence Investigator has been used in a wide range of laboratory settings for over 15 years. This highly advanced yet simple to use analyser has only one moving part, giving the user peace of mind.
The Evidence Investigator contains a host of innovative on-board data analysis features ensuring manual processes are kept to a minimum.
By utilising the same multiplex technology as the other Evidence Series analysers, the Evidence Investigator can process up to 44 results from a single sample, with a maximum throughput of up to 2376 tests per hour. Offering efficiency without compromising on accuracy, the Evidence Investigator is the perfect fit for medium throughput laboratories seeking maximum use of bench space.
Molecular Testing
Our molecular product range offers diagnostic, prognostic and predictive solutions across a variety of disease areas including sexually transmitted infection (STI), Respiratory tract infection, colorectal cancer, familial hypercholesterolemia (FH) and cardiovascular disease (CVD). Additionally, we can provide a wide range of assay formats including single nucleotide polymorphisms (SNP) genotyping, pathogen detection and mutation detection.
Pathogen Detection
STI and Respiratory Arrays
Both arrays detect the most common and frequently requested infections in sexual and respiratory health. These comprehensive, highly sensitive and specific tests enable identification of co-infections simultaneously, often in asymptomatic patients and enable antibiotic stewardship.
Mutation Detection
KRAS, BRAF, PIK3CA array and Familial Hypercholesterolemia Arrays I & II
These unique biochip assays permit high discrimination between multiple targets in a number of genes with a rapid turnaround time (3 hours). The arrays enable detection of the most frequently occurring mutations known to cause disease (FH) and adversely affect patient treatment (KRAS, BRAF, PIK3CA). A unique primer set is designed for each target which will hybridise to a complimentary oligo-nucleotide probe spotted on a biochip discrete test region (DTR).
SNP Genotyping
Cardiovascular Risk Prediction Array
This array identifies individuals with a genetic predisposition to coronary heart disease (CHD). The innovative multiplex primers are designed to discriminate DNA sequences which differ only at one base.
For more information on our Evidence Series or Molecular range of Assays, contact us at EvidenceSeries@randox.com
Assessing the risk of developing Alzheimer’s disease
World Alzheimer’s Month
World Alzheimer’s Month is a global campaign to raise awareness and highlight the challenge that surrounds the disease, hosted by the Alzheimer’s disease International (ADI) every September. During this month World Alzheimer’s Day also takes place, 21 September each year.
47 million people are living with Alzheimer’s worldwide, costing 604 billion USD per year. This number is expected to rise to 76 million people with the disease by 2030.1 The FDA have not approved a medication for the treatment of Alzheimer’s disease since 2003. More than 400 clinical trials are currently looking at new treatments for Alzheimer’s disease (AD) and many of them are actively recruiting. Many still regard the amyloid hypothesis as a key explanation for Alzheimers disease development and progression.2
Alzheimer’s risk
Alzheimer’s disease is not necessarily inherited as a single-gene mutation as the inheritance pattern is incredibly complex. Unlike familial Alzheimer’s disease, a multi-gene form usually affects those aged 65 and older. The gene with the greatest known effect on the risk of developing late-onset Alzheimer’s disease is called apolipoprotein E (APOE). It is found on chromosome 19 and the APOE protein plays a role in handling fats in the body, including cholesterol. 3
ApoE plays a key role in lipid metabolism and the scientific and medical community recognise it as one of the most powerful genetic risk factors for dementia and other neurodegenerative diseases. It has become one of the most widely studied gene variants in Alzheimer’s disease and constitutes a major consideration for preventive medicine.
ApoE exists in three common isoforms (ApoE2, ApoE3 and ApoE4) which are coded by three co-dominant alleles (e2, e3, e4). As such, six common ApoE phenotypes exist within the general population: E2/E2, E3/E3, E4/E4 (homozygous) and E2/E3, E2/E4, E3/E4 (heterozygous). Medical professionals recognise the presence of the ApoE4 isoform as a major genetic risk factor for development of Alzheimer’s disease. Therefore, the availability of analytical methods for rapid and reliable ApoE4 classification is advantageous.
Evidence Investigator
The Apolipoprotein E4 (ApoE4) Array is a research use only product developed for the Evidence Investigator. The ApoE4 Array measures both total ApoE protein levels and ApoE4 protein levels directly from plasma samples and using a ratio can classify patients as negative or positive for ApoE4. In turn we can then assess their risk for the development of Alzheimer’s disease.
2-plex Biochip Array
- Pan ApoE
- ApoE4
An individual’s ApoE status has been shown to affect pre-symptomatic risk, diagnosis, prognosis, and treatment response for a variety of diseases, in particular Alzheimer’s disease. The ApoE4 Array can rapidly and accurately detect an individual’s ApoE4 status directly from a plasma sample. In combination with medical and family history, medication and lifestyle, this can deliver valuable information for personalised medicine approaches.
The 2-plex diagnostic Alzheimer’s test has the utility to detect the likelihood of a person’s chance of developing the disease to assist in the research and development of a potential drug to combat or slow down the process of Alzheimer’s.
1 https://www.alz.org/global/overview.asp
2 https://www.brightfocus.org/alzheimers/article/clinical-trials-alzheimers-disease-whats-new
For further information about the Randox Alzheimer’s Array, please email info@randoxbiosciences.com
The Evidence Series
Having developed the patented Biochip Array Technology following £250 million investment in research and development, we needed a platform that allowed Biochip Array Technology capabilities to be showcased. Step forward the Evidence Series.
The series includes the Evidence, the Evidence Evolution, the Evidence Investigator and the Evidence MultiSTAT. Each analyser has been designed and built with boundary pushing engineering, to ensure financial, labour and time savings for the end user.
Have a read below of the overview of each analyser in the Evidence Series
Evidence Evolution
The world’s first fully automated random-access biochip testing platform, the Evidence Evolution is the world’s most advanced immunoanalyser. With the capability to process up to 2,640 tests per hour, the Evidence Evolution offers complete system integration, as well as the most comprehensive test menu on the market.
Evidence
As the world’s first Biochip Array Technology system, the Evidence immunoanalyser has revolutionised laboratory screening worldwide. With the capability to process 3,960 tests per hour and a sample capacity of 360, the Evidence is ideal for use in a high throughput laboratory.
Evidence Investigator
The Evidence Investigator is a compact, semi-automated benchtop immunoanalyser that offers efficient and comprehensive testing across a range of applications including clinical diagnostics, molecular, toxicology and food diagnostics. The Evidence Investigator boasts a throughput of up to 2,376 tests per hour, offering efficiency without compromising on accuracy.
Evidence MultiSTAT
The Evidence MultiSTAT is a fully automated immunoanalyser that enables on-site simultaneous detection of up to 44 analytes from a single sample of oral fluid, urine or blood. With a three-step process and results generated in less than 20 minutes, the Evidence MultiSTAT is an ideal solution for those with no knowledge of laboratory procedures and offers a throughput of up to 132 tests per hour.
About the Randox Evidence Series
The Evidence Series is set to revolutionise diagnostic testing forever. Offering unrivalled capabilities across all analysers, we truly believe that the Evidence Series range of immunoassay analysers can meet your diagnostic testing capabilities.
For more information on any of the Evidence Series analysers, please visit https://www.randox.com/evidence-series/ or contact us evidenceseries@randox.com.
Randox Biochip Array (BAT) Technology free from Biotin-Streptavidin
Biotin, also known as vitamin B7, is involved with fatty acid metabolism, amino acid degradation, and gluconeogenesis. The recommended daily intake for biotin is roughly 30-70µg, which is extremely low, meaning that biotin deficiency is rare. Recently, there has been a surge in biotin supplementation mainly for beauty reasons, including: stronger nails and healthier skin and hair, resulting in the biotin craze on Instagram. Currently 162K posts are attributed to the biotin hashtag (#biotin) on Instagram. Whilst biotin supplementation is beneficial for numerous health conditions, including: multiple sclerosis (MS), diabetes, elevated cholesterol, and metabolic dysfunction, the increasing use of biotin by patients has created a problem with in vitro diagnostic testing.
With numerous manufacturers using biotin-streptavidin technology to develop in vitro diagnostic tests, combined with the rise in biotin supplementation use, the FDA (food and drug administration) issued an alert regarding the potential for erroneous results triggered by high levels of biotin in patient samples, at the end of 2017. Clinical decisions based on these false results from biotin technology can lead to inaccurate diagnosis and inappropriate treatment prescribed. The FDA confirmed that a patient, who was consuming high levels of biotin, died when a troponin tested was skewed and failed to show that the patient was having a heart attack. Other tests that can produce erroneous results include: cardiac, pregnancy, cancer and iron-deficiency tests.
(Halasey, 2018)
The image above highlights that in biotin-free patient samples, the analyte to be tested successfully binds to the biotinylated antibody and the labelled antibody ultimately ensuring accurate measurement. In the patient sample containing high levels of biotin, the biotin inhibits streptavidin’s ability to capture the analyte-antibody complex, generating falsely lowered results.
As 70% of all clinical decisions are based on results from in vitro diagnostic tests, it is vital that laboratories are selecting in vitro diagnostic tests that do not adopt the biotin-streptavidin technology to ensure accurate patient testing.
Randox do not utilise the biotin-streptavidin technology in the development of the Biochip Array Technology (BAT).
The Randox Biochip facilitates multiplex testing for faster, more comprehensive patient testing. This technology, free from biotin-streptavidin, uses capture antibodies bound to a solid substrate (biochip surface) as opposed to biotinylated antibodies used by other manufacturers. The Biochip also utilises enzyme labelled conjugate to enable chemiluminescent detection of the target in the patient sample.
Biochip test menu
The Biochip Array Technology (BAT) from Randox is capable of simultaneous multi-analyte diagnostic testing within the fields of clinical research and drugs of abuse testing. The technology works through combining a panel of related assays on a single biochip with a single set of reagents, controls and calibrators. An extensive range of Biochip panels are available, each optimised to provide the best performance.
Evidence
The evidence analyser is the world’s first protein Biochip Array Technology system and has truly transformed laboratory diagnostics worldwide. As the first of its kind, the Evidence has introduced higher standards of quality efficiency and reliability to numerous sectors including hospitals and clinical laboratories, forensic and clinical toxicology, pharmaceutical/CRO applications, as well as veterinary laboratories.
Evidence Evolution
The world’s first fully automated random access Biochip testing platform. The Evidence Evolution is set to revolutionise current diagnostic testing. With the capability to process up to 2,640 tests per hour, the Evidence Evolution utilises multiplexing technology, offering advanced test consolidation, patient profiling, a complete system integration, as well as the most comprehensive test menu on the market.
Investigator
The #1 choice for research, clinical, forensic, and veterinary testing. Using the multiplexing technology, the semi-automated benchtop immunoanalyser Evidence Investigator is suitable for medium throughput laboratories. In addition to the current test menu for this analyser, Randox have new tests in development.
Reference:
Halasey. S, 2018, “Inside Track: Biotin Gets a Safety Alert”. Available from URL: http://www.clpmag.com/2018/01/inside-track-biotin-gets-safety-alert/
Evidence Investigator | Adaptable, Efficient & Comprehensive
The Evidence Investigator is a compact, semi-automated benchtop analyser that offers efficient and comprehensive testing across a range of applications including clinical diagnostics, molecular, research, toxicology and food diagnostics.
Renowned for its versatility, robustness and effective reporting methods, the Evidence Investigator has been used in a wide range of laboratory settings for over 15 years. This highly advanced yet simple to use analyser has only one moving part, giving the user peace of mind.
The Evidence Investigator contains a host of innovative on-board data analysis features ensuring manual processes are kept to a minimum.
By utilising the same multiplex technology as the other Evidence Series analysers, the Evidence Investigator can process up to 44 results from a single sample, with a maximum throughput of up to 2376 tests per hour. Offering efficiency without compromising on accuracy, the Evidence Investigator is the perfect fit for medium throughput laboratories seeking maximum use of bench space.
Accurate and Robust
Like all the Evidence Series analysers, what sets it apart is technology. The Evidence Investigator is extremely well equipped to provide reliable results, while simultaneously robust enough to withstand frequent, heavy use.
Results are generated using a Charge Coupled Device (CCD) camera, which quantifies chemiluminescent light. This light measures the degree of binding between the patient sample and specific biochip bound ligands, generating highly accurate and reliable results.
Consolidation
The Evidence Investigator is the world’s first platform allowing consolidation of immunoassay and molecular diagnostics. This is achieved through utilising protein and DNA based biochips. By giving the user the ability to consolidate tests, the Evidence Investigator improves laboratory efficiency and reduces costs.
Advanced Reporting
The Evidence Investigator image processing software translates light signal generated from chemiluminescent reactions into analyte concentration. This removes the need for any manual processing of data.
Previously unreported tests can also be retrieved, so they can be tested retrospectively. This saves time, labour costs and reduces any reagents wastage. All data is then analysed on-board, removing issues related to human error and result manipulation.
About the Randox Evidence Series
The Evidence Series is set to revolutionise diagnostic testing forever. Offering unrivalled capabilities across all analysers, we truly believe that the Evidence Series range of immunoassay analysers can meet your diagnostic testing capabilities.
For more information on the Evidence Investigator, or any of the Evidence Series analysers, visit https://www.randox.com/evidence-series/ or contact us evidenceseries@randox.com.
Randox Food Diagnostics: Infiniplex Array for Milk
Drug residues in milk present major concern for farmers, dairy processors, cheese manufacturers, authorities and consumers due to the potential public health and industrial implications. Through the potential inappropriate antimicrobial use in animals producing product for human consumption, antibiotic-resistant organisms can enter the food supply or can spread to various components of the ecosystem. For consumer protection, regulatory limits have been set for the majority of compounds.
Randox Food Diagnostics provides screening technology to monitor the levels of these potentially harmful compounds including the Infiniplex for Milk Array available on the Evidence Investigator and Evidence Multistat analysers.
Using the Randox Food technology the user can identify 130 analytes from a 200µl sample of raw milk and follows this simple process to results:
- Pipette the sample directly onto the MultiSTAT biochip
- Insert into the Evidence MultiSTAT
- Press Play and follow the on-screen prompts
- Results appear on screen in under 20 minutes
Developed to provide an easy to use option for the user, the Infiniplex Array for Multistat can be used by anyone to ensure rapid on-site testing within the dairy industry.
The InfiniPlex test menu is 98% compliant with EU regulations and screens for additional contaminants including; antiparasitic, anti-inflammatories, non-steroidal and unauthorised substances from one sample of raw milk, creating a better end product for the processor and end user.
To find out more about InfiniPlex contact info@randoxfooddiagnostics.com
The Evidence Evolution – The newest member of the Evidence series
The Evidence Evolution utilises Randox’s cutting-edge Biochip Array Technology, offering diagnostic testing from a single sample. The Evidence Evolution boasts 2640 tests per hour and when put to the test against our competitor machines, the Evidence Evolution gives a true walk away time of up to 2 hours, meaning staff can fully load the machine and get up to 44 results from each sample every minute, while they get on with important laboratory tasks.
The Evidence Evolution has been designed to meet the needs of a variety of laboratories. Delivering quality results, efficiently and economically in forensic and clinical immunoassay locations.
The Evidence Evolution is the latest development in our Evidence Series range, which was first launched in 2002. This trusted technology is powered by Biochip and is used throughout the world in a range of different sites for clinical, toxicology and food testing. The Evidence Series has a range of analysers that can meet the need of any laboratory.
For more information on any of the Evidence Series analysers, please visit https://www.randox.com/evidence-series/ or contact us evidenceseries@randox.com.
The Evidence Series: What is it and how is it changing the diagnostic landscape forever?
Having developed the patented Biochip Array Technology following £250 million investment in diagnostic research and development, we needed a platform that allowed Biochip Array Technology capabilities to be showcased. Step forward the Evidence Series.
The series includes the Evidence, the Evidence Evolution, the Evidence Investigator and the Evidence MultiSTAT. Each analyser has been designed and built with boundary pushing engineering, to ensure financial, labour and time savings for the end user.
Have a read below of the overview of each analyser in the Evidence Series
Evidence Evolution
The world’s first fully automated random-access biochip testing platform, the Evidence Evolution is the world’s most advanced immunoanalyser. With the capability to process up to 2,640 tests per hour, the Evidence Evolution offers complete system integration, as well as the most comprehensive test menu on the market.
Evidence
As the world’s first Biochip Array Technology system, the Evidence immunoanalyser has revolutionised laboratory screening worldwide. With the capability to process 3,960 tests per hour and a sample capacity of 360, the Evidence is ideal for use in a high throughput laboratory.
Evidence Investigator
The Evidence Investigator is a compact, semi-automated benchtop immunoanalyser that offers efficient and comprehensive testing across a range of applications including clinical diagnostics, molecular, toxicology and food diagnostics. The Evidence Investigator boasts a throughput of up to 2,376 tests per hour, offering efficiency without compromising on accuracy.
Evidence MultiSTAT
The Evidence MultiSTAT is a fully automated immunoanalyser that enables on-site simultaneous detection of up to 44 analytes from a single sample of oral fluid, urine or blood. With a three-step process and results generated in less than 20 minutes, the Evidence MultiSTAT is an ideal solution for those with no knowledge of laboratory procedures and offers a throughput of up to 132 tests per hour.
About the Randox Evidence Series
The Evidence Series is set to revolutionise diagnostic testing forever. Offering unrivalled capabilities across all analysers, we truly believe that the Evidence Series range of immunoassay analysers can meet your diagnostic testing capabilities.
For more information on any of the Evidence Series analysers, please visit https://www.randox.com/evidence-series/ or contact us evidenceseries@randox.com.